Hand-Held CCD Spectrometer
• Compact system, can be handheld or securely mounted • Flexible optical input direct to slit or via fiber • Designed from the ground up for applications • Impact resistant housing • High performance electronics • Standard design allows up to a 850 nm measurement window between 200 nm and 1050 nm • USB 1.1 and 2.0 interface with 16-bit dynamic range available • Support up to 8 USB multi-channel configuration • UV enhancing coating
FEATURE | VALUE | |
---|---|---|
Model | SM240 | SM440 |
Detectors | Sony ILX511(UV Enhanced Coated) ▶ Number of Pixels : 2048 ▶ Sensing Pixel Size : 14 μm X 200 μm ▶ Sensitivity : 200V/(lx s) under 3200K uniform illumination |
Toshiba TCD 1304 ▶ Number of Pixels : 3648 ▶ Sensing Pixel Size : 8 μm X 200 μm ▶ Sensitivity : 160V/(lx s) under daylight fluorescent illumination |
Spectrograph # | 2.7 | |
Dark Noise RMS | <50 RMS counts in 16 bits | |
Fiber Coupler | SMA905 or FC standard | |
Wavelength Range | Full Range : 200 ~ 1050 nm UV Range : 200~450 nm VIS Range : 380 ~ 760 nm NIR Range : 550 ~ 1050 nm |
|
Optical Resolution | 0.3 ~ 10 nm FWHM | 0.25 ~ 10 nm FWHM |
Stray Light Level | <0.05% @ 632 nm(<0.1% overall) | |
Computer Interface | USB 1.1/2.0 compatible | |
Operating System | Windows 7/10 (32/64 bit) | |
SDK Support | Visual C++ / Visual Basic / LabVIEW | |
Dimensions / Weight | 142mm X 73mm X 25mm / 0.4Kg |
The Choice for Spectral Applications
The SM240/SM440 is a compact CCD Spectrometer for use with a PC. Based on the SM200/SM400 optical bench design, it supports many different applications where spectral or color measurements are required, including high dynamic range applications.
The SM240/SM440 can accept light directly through its built-in slit or via optical fiber. The durable aluminum housing that encloses the SM240/SM440 provides stable optical bench operation over a wide range of temperatures.
The standard sensor arrays used are the Sony ILX 511 for SM240 and the Toshiba TCD1304 for the SM440. The array driver electronics have been designed for highly sensitive yet stable operation. These arrays (in conjunction with our special UV coating process and custom order sorting filters) allow up to a 850nm measurement window located from 200nm to 1050nm (smaller measurement window sizes increase spectral resolution and light sensitivity). Standard interfaces to the SM240/SM440 include a USB 2.0 interface and a PCI card interface with 16-bit dynamic range. Our USB board can support multichannel configuration up to 8. With this multichannel configuration, a high resolution for wide range or a dual spectrometer system (one for measurement and the other for reference) is possible.
Korea Spectral Products applies new UV enhancing coating on the CCD to increase the UV sensitivity below 450nm comparing with the conventional UV coating that is widely used in CCD spectrometers. By the help of this new UV coating, the signal sensitivity below 500nm can get improved ~20-50% more in general.
The black-anodized housing is available for OEM customers who are using the unit as it is with no need to install the optical bench and the electronic board separately (like SM200/SM400) in their systems. The electronic board is secured in the housing of the SM240/SM440, which is better for the electronic noise protection.
Software support includes a SDK and DLLs for dedicated applications development and our SM32Pro Windows-based spectral acquisition and analysis software. Both standard and legacy interface designs provide support for advanced acquisition programming and external triggering.
ㅣ Software ㅣ Manual ㅣ Catalog ㅣ ▶ Download